CEC Rule 8-200 Residential Load Calculator (Canada)

Canadian Electrical Code (2021 / 2024) Single Dwelling • 100A–200A Service Sizing, EVEMS Rule 8-106(11) & Heat Pumps

100% Client-Side
Presets:
Step 1CEC 8-200(1)(a)(i)-(ii) & 8-110

Service Size & Living Area

Living Area Units
m²
m²

Effective CEC Living Area: 185.0 m² (1,991 sq ft) → Basic Load: 7,000 W (5,000 W first 90 m² + 2 × 1,000 W)

Step 2CEC 8-200(1)(a)(iii), 62-118(3), 8-106(3)

Space Heating & Air Conditioning

W

First 10,000 W @ 100% + remainder @ 75% = 0 W

W

A/C Demand @ 100% = 3,600 W

Step 3CEC 8-200(1)(a)(iv)

Electric Range

W

Range Demand = 6,000 W

Step 4CEC 8-200(1)(a)(v) — 100%

Tankless Water Heaters, Pools, Hot Tubs & Steamers

W
W
W
Step 5CEC 8-200(1)(a)(vi) & 8-106(11)

EV Charger (EVSE) & Load Management (EVEMS)

W
Step 6CEC 8-200(1)(a)(vii)

Other Loads Over 1,500 W

Active Rule: 25% (electric range provided)

W
W
W
W
Add Custom Load (> 1,500 W)
W
FAIL
125.5A / 100A

Frequently Asked Questions — Canadian CEC Rule 8-200

Key Canadian Electrical Code rules for 100A/200A residential services, Rule 8-106(11) EVEMS, and Rule 8-110 living area.

In most 100A Canadian homes, adding an unmanaged 48A (11,520 W) EV charger pushes the CEC Rule 8-200 calculated demand above 100A (24,000 W). However, under CEC Rule 8-106(11), if your EV charger is controlled by an approved Electric Vehicle Energy Management System (EVEMS) such as a DCC-9, BlackBox, or Wallbox Power Meter, the EVSE load is excluded (0 W) from the calculated service demand—often avoiding a $4,000–$8,000 200A service upgrade.