NEC 220.87 Existing Load (Utility Demand) Calculator

1-Year Utility Billing Peak or 30-Day 15-Min Interval Data (× 125%) + New EVSE / Heat Pump Loads

100% Client-Side
Presets:
Step 1NEC 220.87

Existing Service Size & Utility Peak Demand

Existing Peak: 8,000 VA × 125% (NEC 220.87) = 10,000 VA

Step 2NEC Art. 220 & 220.57

New Loads to Be Added

W
W
Other New Loads (100% Nameplate)
W
W
W
Add Custom New Load
W
PASS
81.7A / 100A

Frequently Asked Questions — NEC 220.87 Utility Demand Load Calc

Key code rules for 1-year / 30-day utility peak demand, seasonal adjustments, and NEC 220.57 EVSE minimums.

NEC 220.82 estimates residential demand from square footage and appliance nameplates, which can sometimes overstate real-world usage on older 100A or 150A panels. NEC 220.87 allows you to determine the existing load using actual utility peak demand data (either 1-year billing peak or a 30-day 15-minute interval recording) multiplied by 125%, plus the new load(s) you are adding—often proving an EV charger or heat pump fits without a panel upgrade.